NUMBDES
Minimum value = 2000, maximum value = 5000 (decimal). Default = 4000;
This parameter allows resources to be tuned for the number of devices. Each BDE
resource consumes 12 bytes of memory. The default value should be satisfactory for
most cases.
NUMDEVICES
Minimum value = 0, maximum value = 1000 (decimal). Default = 400;
NUMDEVICES specifies the maximum number of target devices that might be
connected to the fabric. The default value should be satisfactory for most cases.
NOTE: To allow for loop operations, 126 additional devices are always enabled.
N_TIMEOUT
Minimum value = 0, maximum value = 300 (decimal). Default = 20;
Node timeout controls a "second chance" for a "disappearing" device. After events such
as cable disconnect/reconnect or drive removal/insertion, the driver checks what
devices it has found. If that list does not include a previously found device, and this
value is not 0, the driver waits the specified number of seconds and then restarts the
checking. If the device is found on the second try, then the device is considered to be
available; if it is still not found, the driver will reject any further attempts to access it.
The default value should be satisfactory for most cases. CLARiiON RAID arrays may
require setting the value to 90.
RSCNADISC
Boolean parameter: 0 = not selected, 1 = selected. Default is RSCNADISC=1;
RSCNADISC is used in link error recovery situations. When set to 1 (default), the
system uses ADISC when possible to rediscover a node. If set to 0, only PLOGI is
used.