lpfcN: 9 : FAN received
A FAN ELS command was received from a fabric. The assigned PortID and
internal driver state are recorded.
ACTION: None needed.
WARNING DISCOVERY verbose fcelsb.c
lpfcN: 10 : RSCN received
A RSCN ELS command was received from a fabric. The internal driver state and
size of the RSCN payload is recorded.
ACTION: None needed.
WARNING DISCOVERY verbose fcelsb.c
lpfcN: 11 : Unknown Identifier in RSCN payload
Typically the identifier in the RSCN payload specifies a domain, area or a specific
NportID. If none of these are specified, a warning will be recorded. The value of the
illegal identifier will be recorded.
ACTION: Potential problem with the fabric. Check with the fabric vendor.
WARNING always fcelsb.c