Emulex ONECONNECT OCE10102-F Guida Utente Pagina 27

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 36
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 26
(2) Select the Converged Network Adapter card to be set (BIOS setting) in the [Select Host Adapter]
window.
The [Fast!UTIL Options] menu appears. Then perform Step 3 through Step 10.
11 Select [Exit Fast!UTIL] and press the [Enter] key.
12 Select [Reboot System] and press the [Enter] key.
Exit Fast!UTIL
Reboot System
Return to Fast!UTIL
The server reboots.
To return to the [Fast!UTIL] menu, select [Return to Fast!UTIL].
2.2.2 Setting Up SAN Boot
Refer to "Server Support Matrix" to check the support status of SAN Boot and refer to the manual of the serv-
er, OS, or the Converged Network Adapter card that is to be used.
When using a logical unit (LUN) of the ETERNUS DX
storage systems as a boot disk, make sure that the LUN
has enough capacity to install the OS.
2.2.3 Setting the Selectable Boot
1 Select [Selectable Boot Settings] from the [Configuration Settings] menu and press the [Enter] key.
2 Set [Selectable Boot] to "Enabled".
3 Select a boot path (ETERNUS DX
port WWN) and boot LUN#.
The boot path and boot LUN# selection window only appears when [Host Adapter BIOS] is "Enabled"
in [SAN Boot].
If [Host Adapter BIOS] is "Disabled", the boot path and boot LUN# selection window does not appear.
Instead, the window shown in Step 4 appears when [Selectable Boot Settings] is selected.
Chapter 2 Setup Procedure for QLogic Converged Network Adapter Cards
2.2 Setting Up the Converged Network Adapter Cards
27
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection-
(FCoE) for VMware
®
ESX
Copyright 2014 FUJITSU LIMITED
P3AM-4772-10ENZ0
Vedere la pagina 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 35 36

Commenti su questo manuale

Nessun commento